RANCANG BANGUN ALAT PENDETEKSI GOLONGAN DARAH DAN SATURASI OKSIGEN BERBASIS ARDUINO UNO

  • Ahmad Halim Universitas Islam Nusantara, Indonesia
  • Ganis Sanhaji Universitas Islam Nusantara, Indonesia
  • Yudha Aria Praja Universitas Islam Nusantara, Indonesia
Keywords: Blood type, ABO System, Oxygen Saturation, SpO2, Arduino Uno, TCRT5000 Sensor, MAX30100 Sensor

Abstract

In this study a device was designed to detect human blood group using the ABO method which is integrated with a blood oxygen saturation meter. This tool can detect agglutination or non-agglutination reactions in blood samples that have been treated with antisera and will then be read by three TCRT5000 sensors which are reflective sensors used as detectors of A, B and Rhesus antigens when agglutination and non-agglutination reactions occur on paper. blood sample test. In addition, the MAX30100 sensor is also used to measure blood oxygen saturation in the human body. Data that has been read by the sensor will be directly processed by Arduino Uno and the results from reading by the sensor will be displayed on the 16x2 LCD. In testing the human blood group detector designed where the results of all tests on the respondent's blood samples totaling 8 blood samples obtained a success value of 100%. In addition, the results of testing the Oxygen Saturation Measuring Instrument using the MAX30100 sensor obtained an accuracy value of 99.53%.

Downloads

Download data is not yet available.

References

Aditya, L., & Wahyuni, R. D. (2020). Rancang Bangun Alat Pengukur Kadar Oksigen Non Invasive Menggunakan Sensor Max30100. Jurnal Elektro, 8(2), 72-80.

Andrian W, R. (2017). ALAT UJI GOLONGAN DARAH SISTEM ABO DAN RHESUS (Doctoral dissertation, Universitas Widya Husada Semarang).

Andiani, N., & Akmaliah, I. F. (2012). Alat Pendeteksi Golongan Darah Manusia Berbasis Mikrokontroler 89s51. Prosiding SNATIKA.

Budi, D. B. S., Maulana, R., & Fitriyah, H. (2019). Sistem deteksi gejala Hipoksia berdasarkan saturasi oksigen dan detak jantung menggunakan metode fuzzy berbasis arduino. Jurnal Pengembangan Teknologi Informasi dan Ilmu Komputer, 3(2), 1925-1933.

Ghifari, H. G., Darlis, D., & Hartaman, A. (2021). Pendeteksi Golongan Darah Manusia Berbasis Tensorflow menggunakan ESP32-CAM. ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika, 9(2), 359.

Handono, J., Wijaya, S. K., & Ibrahim, A. S. (2017). Deteksi Aglutinasi Secara Otomatis Untuk Uji Golongan Darah Tipe ABO Berbasis Kertas. FaST-Jurnal Sains dan Teknologi (Journal of Science and Technology), 1(1), 15-25.

Hastiningsih, (2016). Alat Pendeteksi Golongan Darah Manusia Berbasis Arduino Uno. Politeknik Muhammadiyah Yogyakarta. Sumber : http://repository.umy.ac.id/handle/123456789/4641. Diakses 09 Juli 2020;

Huda, C., & Waluyo, A. (2022). Modified prone position pada pasien long covid-19 untuk meningkatkan saturasi oksigen perifer. Jurnal Keperawatan Silampari, 5(2), 1096-1104.

Khan, M. S., Thouas, G., Shen, W., Whyte, G., & Garnier, G. (2010). Paper diagnostic for instantaneous blood typing. Analytical chemistry, 82(10), 4158-4164.

Kusumayudha, S. B. (2010). Model Konseptual Hidrogeologi Kubah Kulonprogo Berdasarkan Pemetaan dan Analisis Geometri Fraktal. PROCCEDINGS PIT IAGI LOMBOK.

Muchlas, M., Sutikno, T., & Santiko, S. (2007). PERANCANGAN ALAT UKUR GOLONGAN DARAH BERBASIS MIKROKONTROLER AT89S52. TELKOMNIKA (Telecommunication Computing Electronics and Control), 5(2), 107-112.

Melati, E., Passarella, R., Primartha, R., & Murdiansyah, A. (2011). Desain dan pembuatan alat pendeteksi golongan darah menggunakan mikrokontroler. Generic, 6(2), 52-60

Nugroho, C. R. (2019). Alat pengukur saturasi oksigen dalam darah menggunakan metode PPG reflectance pada sensor MAX30100 (Bachelor's thesis, Fakultas Sains dan Teknologi Universitas Islam Negeri Syarif Hidayatullah Jakarta).

Nugroho, C. R. (2019). Alat pengukur saturasi oksigen dalam darah menggunakan metode PPG reflectance pada sensor MAX30100 (Bachelor's thesis, Fakultas Sains dan Teknologi Universitas Islam Negeri Syarif Hidayatullah Jakarta).

Noiphung, J., Talalak, K., Hongwarittorrn, I., Pupinyo, N., Thirabowonkitphithan, P., & Laiwattanapaisal, W. (2015). A novel paper-based assay for the simultaneous determination of Rh typing and forward and reverse ABO blood groups. Biosensors and Bioelectronics, 67, 485-489.

Oktari, A., & Silvia, N. D. (2016). Pemeriksaan Golongan Darah Sistem ABO Metode Slide dengan Reagen Serum Golongan Darah A, B, O. Jurnal Teknologi Laboratorium, 5(2), 49-54.

Pramartaningthyas, E. K., & Endarko, E. (2012). Kajian Karakteristrik Alat Ukur dan Sensor Standar pada Proses Kalibrasi Data Sensor Cahaya. Jurnal Fisika dan Aplikasinya, 8(2), 120206-1

Sepdianto, T. C., Tyas, M. D. C., & Anjaswarni, T. (2016). Peningkatan Saturasi Oksigen Melalui Latihan Deep Diaphragmatic Breathing pada Pasien Gagal Jantung. Jurnal Ilmu Keperawatan dan Kebidanan, 5(1).

Triwijayanti, A. (2015). STUDI DESKRIPTIF PEMBERIAN OKSIGEN DENGAN HEAD BOX TERHADAP PENINGKATAN SATURASI OKSIGEN PADA NEONATUS DI RUANG PERINATALOGI RSI KENDAL. FIKkeS, 8(2).

Yonanto, V., Wisana, I. D. G. H., & Rahmawati, T. (2019). Pemantauan SpO2 Melalui Aplikasi Android di Mobile Phone. TEKNOKES, 12(2), 21-27.

Published
2023-08-30
How to Cite
Halim, A., Sanhaji, G., & Praja, Y. (2023). RANCANG BANGUN ALAT PENDETEKSI GOLONGAN DARAH DAN SATURASI OKSIGEN BERBASIS ARDUINO UNO. EDUSAINTEK: Jurnal Pendidikan, Sains Dan Teknologi, 11(1), 300 - 315. https://doi.org/10.47668/edusaintek.v11i1.962
Section
Articles